Difference Between RSA306 and RSA306B

The primary differences between RSA306 and RSA306B are the RSA306B has the following improvements:


Diese FAQ bezieht sich auf:
RSA306, RSA306B
474076
Host ID when using SignalVu-PC

To find the Host Id while using SignalVu-PC select


Diese FAQ bezieht sich auf:
SIGNALVU-PC-SVE
474071
Arb Sweep in MDO3000, MDO4000C, and 5 series MSO

AFG in MDO3000, MDO4000C, and 5 Series MSO do not have sweep function. But a limited sweep may be created using the arbitrary function.

 

Example: Create a sweep from 100 KHz to 250 KHz.


Diese FAQ bezieht sich auf:
MDO3012, MDO3014, MDO3022, MDO3024, MDO3032, MDO3034, MDO3052, MDO3054, MDO4024C, MDO4034C, MDO4054C, MDO4104C, MSO54, MSO56, MSO58
474056
Where can I locate the save on trigger feature on the 5 series MSO?

It is in the “Acquisition” badge located in the lower right corner of the screen. It allows the user to set the configuration to save the waveform file or screen capture when there is a triggered event.


Diese FAQ bezieht sich auf:
MSO54, MSO56, MSO58
474041
Can multiple auto measurements be removed at once on the 5 series MSO?

No. Currently, the user interface does not allow to remove all auto measurements at once. The closest workaround will be recalling the default setup.


Diese FAQ bezieht sich auf:
MSO54, MSO56, MSO58
474036
Is e*scope supported on the 5 or 6 series MSO with the Windows 10 installed?

Yes.  With firmware v1.8 or above, using the web browser access to the Windows 10 version is supported along with TightVNC.  TightVNC must be installed on both the remote PC and the scope.  For the detailed setup instructions, please see the 5/6 series online help manual.
Diese FAQ bezieht sich auf:
MSO54, MSO56, MSO58, MSO64

474031
Is BUS trigger mode supported in the AB sequence trigger mode on the 5 series MSO?

Yes. However, it does not apply to both events. It could be only either A or B event for the bus trigger. The second event is locked to edge trigger type.


Diese FAQ bezieht sich auf:
MSO54, MSO56, MSO58
474026
When upgrading firmware get “Cannot establish connection: Connection timed out”.

Make sure that the instrument is in upgrade mode. On the instrument itself, navigate to Config -> Utilities -> System Upgrade -> Network Upgrade and select “continue” by pushing the ”SEL” button.
Diese FAQ bezieht sich auf:
WFM5000, WFM5200, WFM5250, WFM7120, WFM7200, WFM8200, WFM8300, WVR5200, WVR5250, WVR7120, WVR7200, WVR8200, WVR8300

473216
DMM6500 Scan Temperature Channels using 2001-TCSCAN CardCycle power to the 6500. Select TEMP. Press MENU. In the CHANNEL column, select Settings. Select channel 1. Select Function to Temperature. Select Transducer to CJC2001. Select Unit to F. Select Channel 2.
Diese FAQ bezieht sich auf:
2001-TCSCAN, DMM6500
471676
How do I perform a digitized current measurement on a Keithley DMM6500?

For this example: making a 1kS/s digitized current measurement with 2000 Samples.


Diese FAQ bezieht sich auf:
DAQ6510, DMM6500
471651